Product

You are here:

SLS-B+C30/1+1 – Lightning & surge arrestor for single phase lines (F + N) 220 V

Combined type 1 and 2 (Class B + C) protector, suitable for protection of low voltage lines against lightning strikes and surges of up to 25kA (10/350) in TT (TNS) networks. Recommended for industrial facilities, buildings with a risk of lightning strikes, or fed by overhead lines


SLS-B+C30/3+1 – Lightning and surge arrester for three phase lines (3F+N)380 V.

Combined type 1 and 2 (Class B + C) protector, suitable for protection of low voltage lines against lightning strikes and surges of up to 25kA (10/350) in TT (TNS) networks. Recommended for industrial facilities, buildings with a risk of lightning strikes, or fed by overhead lines.


SLS-B+C100/1+1 – Lightning and surge arrester for single phase lines (F + N) 220 V.

Combined type 1 and 2 (Class B + C) protector, suitable for protection of low voltage lines against lightning strikes and surges ofup to 50kA (10/350) in TT (TNS) networks. Recommended for industrial facilities, systems and buildings with external lightning protection.


SLS-B+C100/3+1 – Lightning and surge arrester for three phase lines (3F+N) 380 V.

Combined type 1 and 2 (Class B + C) protector, suitable for protection of low voltage lines against lightning strikes and transitory surges of up to 100kA (10/350) in TT (TNS) networks. Recommended for industrial facilities, systems and buildings with external lightning protection


SLS-C20/1+1 – Lightning and surge arrester for single lines (F+N) de 220 V.

Type 2 (Class C) protector, suitable for protection of low voltage lines against lightning strikes and transitory surges of up to 20kA (8/20) in TT (TNS) networks. Recommended for industrial installations, distribution boards, buildings with low risk of receiving lightning strikes or fed by underground power lines.


SLS-C20/3+1 – Lightning and surge arrester for three phase lines (3F+N) 220 V.

Type 2 (Class C) protector, suitable for protection of low voltage lines against lightning strikes and transitory surges of up to40kA (8/20) in TT (TNS) networks. Recommended for industrial installations, distribution boards, buildings with low risk of receiving lightning strikes or fed by underground power lines. Recommended for industrial installations, distribution boards, buildings with low risk of receiving lightning strikes or fed by underground power lines.



SPARK GAP MODEL VX-1 – Spark gap for separation model VX-1 (with or without connection terminals).

The separation spark gap is developed to electrically separate the conductive systems that should not have electric contact in their normal state of function. Indicate for the TV scape